Pipe Characteristics Report
This report lists details about every pipe in the network, including the flow and pressure losses in each pipe and it’s fittings. Units for each quantity are included in the column headings in accordance with the units selected on the Project Tab Page.
PIPE No.
The number of each pipe. There is one entry on these pages for every pipe in the network and they are listed in ascending order.
PIPE NODES
The node numbers at the end of each pipe. The order in each pipe, that these are listed is in the direction of water flow. This may be the same as or reverse order to that entered by the user.
FLOW
The flow through each pipe.
PIPE/FTG. NOMINAL DIAMETER
The nominal diameter of each pipe or fitting. If the user enters the actual internal diameter (by entering a negative value) a value will not appear here. One line is listed for each pipe with an additional line for each fitting.
PIPE/FTG. ACTUAL DIAMETER
The actual internal diameter of each pipe as stored in the program or extracted from the user defined pipes according to the entered pipe material or as entered (with a negative sign) on the Pipes Tab Page. For fittings the equivalent length specified in the various Codes is based on a particular pipe material type. For copper pipes it is Type B (ASDB) but for all other copper pipe materials it is assumed that the fitting diameter is the same as the pipe diameter and hence no diameter correction is made For steel and cast iron, with NFPA, the fitting equivalent lengths are for AS40 Medium Weight Steel pipe to ASTM A-135, A-795 and for all other codes, ASAM Medium Weight Steel pipe to AS1074 up to 150mm diameter and above 150mm AS40 Medium Weight Steel pipe to ASTM A-135, A-795. For all other steel pipes a correction for the different internal diameter is made on the basis that the steel fitting always has an internal diameter of the medium weight steel pipe. When for example a Standard Weight Steel (ASTD) pipe is used, the fitting equivalent length is corrected by the diameter ratio to the power 4.85 and the internal diameter of the AS40 or ASAM steel pipe is listed in this column.
For Stainless Steel the fittings are usually welded and line size. The equivalent lengths are therefore taken as the same as for steel with a correction for the different Hazen Williams coefficient but no diameter correction.
PIPE/FTG. CODE
The pipe material or fitting code selected by the user to describe the pipe material or fitting type.
PRESSURE DROP/GAIN DUE TO BOOSTER PUMPS, BKFPs, ETC.
Where a pipe contains a:
Booster Pump, the pressure gain is listed as a negative loss.
BKFP or Pressure Control Device the pressure loss is listed
Tank Exit, the Equivalent length is listed as well as the loss coefficient and the actual pressure drop.
LENGTH
The entered pipe length, or the fitting equivalent length. The equivalent length of each fitting is based on a fitting diameter that may not correspond to the pipe internal diameter. Therefore if the fitting is of a different size to the pipe, then the equivalent length is normalised to the actual pipe size, e.g.. If in a 100mm light weight steel pipe a standard elbow is entered, the elbow will have a diameter of that of medium steel pipe. The equivalent length is increased by D1/D2 to the power 4.87 where D1 and D2 are the internal diameters of light and medium steel pipe respectively. The same correction is applied if a fitting of different size to the pipe is included in the pipe. E.g. SE(40) in a 50mm pipe.
TOTAL LENGTH
The sum of the length of the pipe and the equivalent lengths of all the fittings in this pipe.
HEAD LOSS PER UNIT LENGTH
The friction pressure loss per unit length of straight pipe for this pipe diameter and with this flow. When checking the results this value is a very useful indicator if a pipe size has been incorrectly entered or there is something wrong with the connectivity.
HEAD LOSS OVER PIPE
The total friction pressure loss over the length of the pipe, ie the product of the two preceding columns.
STATIC HEAD LOSS
The static pressure loss due to the difference in elevation between the nodes at each end of the pipe. i.e. the pressure equivalent of the elevation of the first node minus the second node.
THE TOTAL HEAD LOSS
This is the sum of the previous two columns. It may be negative if the static gain is greater than the friction losses.
H\&W COEFFICIENT/ROUGHNESS>
The Hazen Williams Coefficient or Roughness of this pipe depending on the calculation method (selected on the Project Screen) – Hazen Williams or Darcy-Weisbach. For Hazen Williams the H\&W C value on which the fitting equivalent length is based on (as stipulated in the relevant Sprinkler Code) is listed if it is different to the pipe H\&W C value. The program uses this to correct the fitting equivalent length by the ratio of the C value ratio to the power 1.85 as required by the Code. The correction to fitting pressure loss when the using the Darcy formula is based on the equivalent C value to give the same pressure loss for the fitting and the equivalent C value used is listed.
WATER VELOCITY
The velocity of the water in this pipe. This is useful in determining whether the velocity exceeds water velocity restrictions and in determining the time required in dry pipe systems, for water to reach remote parts of the system.
VELOCITY PRESSURE
Although velocity pressure is only included when requested the value is always listed.
Legend
A legend of all fittings used in the network, including User Fittings, is printed at the end of the report with a description of each fitting. The legend also list any User Pipes that have been used.
Below the legend the following information is listed
- pipes with higher velocities than those specified under Warning if Velocity Exceeds on the Project Tab Page,
- pipes with very low flow (below 0.1 units of flow),
- information about how well the program has converged is listed, i.e.
Maximum unbalanced head loss = 0.00008 kPa
Maximum unbalanced flow is = 0.00155 l/m and occurs in Pipe Loop 42