HYENA VERSION 6.11.0
This update includes the following:
- Inclusion of High Density Polyethylene (HDPE) pipes and fittings for SDRās of 9. 11 and 13.5
- Inclusion of Stainless Steel pipes to ANSI/ASME B36.19M Schedule 10s andĀ Ā Schedule 40S down to 8 mm (5/16 inch) diameter for use in Mist systems.
- Extrapolation of fitting equivalent lengths for copper and stainless steel pipes down to 8 mm for use in Mist systems.
- Provision for entry of User defined stainless steel tubing for use in Mist systems for a full range of 17 diameters from 6 mm (1/4 inch) to 50mm (2 inch).Ā Ā Stainless steel tubing pipe diameters are a function of system pressure and hence have to be entered by the user.
- Inclusion of braided flexible pipes where the length is entered as the equivalent length of 25mm diameter steel pipes.
- Addition of a tank exit fitting for Fixed Input point for inclusion when this is a tank.
- New input for Hydrants with the required minimum flow and pressure and the maximum pressure. Program then calculates the k factor for determining the most disadvantaged hydrant.
- The REMOTE option now works with āFind required flow and pressureā
- Find required flow and pressureā now works with multiple input points.
- Provision to find the required minimum flow and pressure of a booster pump when required.
- Calculation of Net Positive Suction Head (NPSH) for any pumps in the system
- Provision for entry of a āMeasurement Nodeā where the flow and pressure of this is listed in the Summary results.
- Right clicking mouse on pipe length provides a calculator to accumulate entered pipe lengths.
- Corrections to the GRID display which was not always displaying entered configuration correctly
- Correction of a bug that caused the flow for the first point on the Q185 curve for the input to be non zero when the type was changed from a fixed pressure.
HYENA VERSION 6.10.2
This update corrects a couple of bugs in version 6.10.1 and includes the following new features:
- In the input for a GRID, a 3D view has been added when viewing the GRID
- In the results, any error messages in the calculations are coloured red and any warning messages are coloured blue.
HYENA VERSION 6.10.1
In this update, a number of minor but annoying bugs have been corrected and the fitting equivalent lengths for the Singapore Standard CP52 Sprinkler Code have been updated to the latest edition (2004). Also the maximum node unbalanced flow as required by most of the Sprinkler codes is now reported in the Summary Results and at the foot of the Pipe Characteristics.
HYENA VERSION 6.10.0
With this update to HYENA (from version 6.00.2 to 6.10.0), provision has been made for the use of the Darcy Weisbach formula in lieu of the Hazen Williams formula for calculating pipe function loss. The Hazen Williams formula as required by NFPA, AS2118 and the other sprinkler codes is only applicable to water flow in pipes. The Darcy Weisbach formula includes the density and viscosity of the fluid and hence can be used, for example, for sea water or water with additives. It is also required to be used for analysing Mist systems when the velocity exceeds 7.5 m/s (for NFPA750) and 6 m/s (for AS4587)
Other enhancements/changes include:
- When REMOTE is run (with the GRID commands) the most favorable area of operation, within the selected REMOTE area, is now identified as well as the least favorable area.
- When entering internal pipe diameters (on the Pipes screen) using a minus sign, the diameter that can be entered has been increased from 600mm to 1200mm
- Equivalent lengths for fittings in accordance with NFPA750 and AS4587 (Mist Systems) have been included
- Pressure control devices including orifice plates and pressure regulators can now be entered and/or sized
- Equivalent lengths for fittings in accordance with the Chinese Standard for Automatic Fire Sprinkler Systems (GB50084) have been included
- There have also been a number of minor bug fixes.