Flow 1, Pressure 1, ..........
A series of up to eight flow/pressure points on the pump or water supply curve at the input point. The first value of flow must be zero and the first pressure is the shut off pressure.
If CURVE is being used the number of pairs of points must be eight, and after the first two flows are entered the remaining flows are extrapolated using the same increment for each pair. They may be changed as necessary.
Note that only one pump curve may be described with each input node. If two parallel pumps are present, then:
-Â If the pumps have the same characteristic, enter 2 under number of pumps (only applies if CURVE is used.)
-Â If the pumps have different characteristics, create a second input point close to the first one. Assign to this second input node the same elevation and set of Flow/Pressure values as for the first one.