Fixed/Curve/Linear/Q185
A selection for:
- FIXED A fixed pressure at an input point in which case only Pressure 1 is entered.
If the input pressure is not a constant, but a curve (e.g. if the input is a pump, the pressure will drop off as the flow increases), then the curve can be described in one of three ways:
- LINEAR signifies a pump or variable water supply pressure being entered as a series of (at least two) points on a curve of pressure vs flow. The program linearly interpolates between the entered points.
- CURVE signifies a pump or variable water supply pressure but in this case a series of coefficients are calculated from the entered values of flow and pressure for a polynomial fit to the points. At least eight points must be entered. This is a slightly more accurate method of describing a pump curve than the LINEAR method.
The polynomial takes the form:
p = a + bq + cq2 + dq3
where:
q is the flow and
a, b, c, d are the coefficients which are displayed on the graph and inserted in the input data file for use in the calculations.
- Q185 signifies a variable water supply pressure where the pressure between each pair of entered points is proportional to the flow to the power 1.85.
If the program is calculating the “Input Point Flow/Pressure”, then pressure 1 is used as a first guess for the iterations carried out by the program.